DOUT1.STATEU AND DOUT2.STATEU

Description

Set the state of the digital output node as follows:

0 = deactivated

1 = activated

DOUT1.STATEU and DOUT2.STATEU are used when DOUTx.MODE = 0 (user mode).


  • AKD-C and AKD-N only support DOUT1.

General Information

Type

R/W Parameter

Units

N/A

Range

0 to 1

Default Value

0

Data Type

Integer

Start Version

M_01-01-01-000

Variants Supported

Variant

Supported

AKD Base Yes
AKD with Position Indexer Yes
AKD EtherCAT Yes
AKD CANopen Yes
AKD BASIC Yes
AKD SynqNet Yes*
AKD EtherNet/IP Yes
AKD PROFINET Yes
AKD Sercos® III Yes
AKD-N Yes
AKD-C Yes

*In SynqNet, a parameter may be available in the firmware but have no effect on the system. See SynqNet Supported Parameters.

Fieldbus Information

If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type. For information on SynqNet parameters see SynqNet Supported Parameters.

PROFINET and Sercos® III
Parameter Fieldbus Address Attributes Signed?
DOUT1.STATEU

PROFINET

2102 Byte No
Sercos® III 2 Octets
DOUT2.STATEU

PROFINET

2107 Byte
Sercos® III 2 Octets
EtherNet/IP
Parameter Instance Data Size Data Type
DOUT1.STATEU 103 1 Byte Integer
DOUT2.STATEU 108
Modbus
Command Register Address Is 64 bit? Attributes Signed? Object Start Version
DOUT1.STATEU 204 No 8 bit No M_01-03-00-000
DOUT2.STATEU 214

Related Topics

Digital Outputs